← All solutions

For imaging product teams and clinical partners

Add risk guarantees
to your imaging AI.

Choose the finding, the mistake and the risk you can accept. We establish what your evidence supports: fewer additional checks, or an AI answer that keeps unresolved findings visible.*

Clinical interpretation, referral decisions and final reporting remain in the clinical workflow.

* Statistical guarantees concern a defined error and population, after calibration and under stated assumptions. Individual errors can remain. Scope & conditions ↗︎

Choose the decision you want to support

One approach. Three distinct guarantees.

OCT research B-scan from OLIVES

OCT · Finding to preliminary draft

Fewer extra finding checks.
A guaranteed limit on incorrect findings.

Bound the percentage of incorrect AI findings among those eligible to skip additional verification, before audit selection.*

The finding remains preliminary. Final clinical review stays in place.

See the OCT example Inspect the exact claim
Fundus research photograph from IDRiD

Fundus · Additional image grading

Fewer extra grading checks.
A guaranteed limit on overlooked review needs.

Bound the percentage of images needing review among those eligible to skip additional grading, before audit selection.*

Existing referral flags, image-quality checks and screening responsibilities remain.

See the fundus example Inspect the exact claim
Chest X-ray research image from NIH ChestX-ray14

Chest X-ray · Pleural-effusion output

Keep uncertainty visible.
A guaranteed limit on reference misses.

Bound the risk that the answer set excludes the expert reference across all in-scope studies, including unresolved answers.*

A single or unresolved suggestion accompanies the radiologist’s reading.

See the chest X-ray example Inspect the exact claim

OCT and fundus use real research images with simulated policies and prepared outcomes. Chest X-ray replays a separate historical CheXpert calculation; its NIH practice images have no transferred guarantee.

Research image sources

Chest X-ray: NIH ChestX-ray14, provided by the NIH Clinical Center. Wang et al., ChestX-ray8: Hospital-scale Chest X-ray Database and Benchmarks on Weakly-Supervised Classification and Localization of Common Thorax Diseases, CVPR 2017, pp. 3462–3471. Use and attribution. Fundus: IDRiD, Porwal et al., CC BY 4.0. OCT: OLIVES, original dataset CC BY 4.0; author-hosted dataset-viewer JPEGs. Image files are unchanged. Full provenance and source limits are available in each walkthrough.

The additional capability

Keep your model.
Establish the risk statement your product can support.

Scores and thresholds help decide what an imaging product shows or checks. EyeTrustAI adds a calibrated policy with an explicit error definition, population and statistical statement. Compare it with your current controls on independent evidence.

OCT

Target an additional verification step.

Establish which findings may enter a preliminary draft without a separate verification task, while retaining final clinical review.

Fundus

Target additional grading.

Assess routine-eligible image results and the extra grading workload. The selected-image error bound is different from screening sensitivity.

Chest X-ray

Retain an unresolved output.

Keep both possibilities visible when the policy does not support a single answer. Whole-population coverage is different from accuracy among single answers.

What exactly would the guarantee cover?

Each task needs its own error definition, reference protocol, population, model/scorer versions and statistical assumptions. OCT and fundus concern errors in a selected group before audits. Chest X-ray concerns reference-label inclusion across all in-scope studies.

Account for patient and site dependence, acquisition devices, image quality, related scans and prior use of the data. Calibration and an independent assessment must support the intended claim; real research images alone do not establish it.

These guarantees do not establish correct diagnoses for every patient, complete an examination or replace clinical and deployment approvals. A model or population change can require reassessment.

Compare the claims

Where it fits

After your model output.
Before the specific checking or display decision.

  1. 01 / Your imaging product

    Image + versioned AI output

    Keep image references, findings or grades, scores, quality flags, patient/encounter grouping and model/device versions.

  2. 02 / EyeTrustAI

    Assessment + supported policy

    Return the supported checking instruction or answer set, with policy and scope identity. Retain the task’s fallback when support is unavailable.

  3. 03 / Your clinical workflow

    Existing review and reporting

    OCT: preliminary findings and final review. Fundus: grading, referral and encounter completion. Chest X-ray: radiologist interpretation and reporting.

Proposed integration pattern. The walkthroughs use fictional applications; they do not supply production clinical connectors or patient-level workflow automation.

Interfaces, ownership and fallback

Scope the model/scorer interface, source access, study identifiers, version checks, latency, hosting and data handling. Keep clinical images and existing alerts available when the policy cannot be applied.

The product team owns integration and operation. Clinical partners own references, escalation, clinical review and care decisions. EyeTrustAI supplies statistical design, calibration and comparison for the agreed task.

Choose a technical or clinical path

The value for your team

A product capability.
A clinical evaluation.
A defined integration.

Imaging product & AI teams

Offer a quality commitment with a defined scope.

Keep your finding model or grader. Evaluate a supported risk limit alongside the unresolved outputs, retained checks and operating cost.

Discuss your product workflow

Clinical teams & research partners

Establish credible references and usefulness.

Select one finding, define how readers handle disagreement and assess whether the proposed review policy improves a real task.

Discuss a clinical collaboration

Device & integration partners

Connect one existing interpretation workflow.

Confirm the model output and software owner first. Device, population and task changes require their own evidence and integration scope.

Explore integration

Choose a useful first scope

Your finding. Your population.
Your clinical reference.

The examples cover an OCT fluid finding, fundus review needs and a pleural-effusion answer set. Another finding, modality, device or population needs a matching evaluation. Retinal gene ranking is a different task; the OCT example illustrates a workflow rather than validating gene candidates.

Reusable evidence

Reviewed examples may help.

Check model versions, reference definitions, patient overlap, acquisition conditions and prior use in model development before assigning evidence to calibration or evaluation.

Assess the evidence you have

Unit of work

An image is not an entire examination.

One photograph or B-scan does not establish a patient-level outcome. Define how ungradable inputs, multiple images, referral decisions and follow-up remain handled.

A practical starting point

Name the task that would change.

Choose one extra grading or verification step, or a defined AI display decision. Bring its product owner and clinical reviewers.

Scope an evaluation

The evidence behind the promise

Keep the statistical claim
and the demonstration distinct.

The method

Conformal prediction and risk control.

Choose a statistical statement that matches the task and denominator. A selected-error claim and whole-population coverage answer different questions.

Compare the guarantees

Today’s demonstrations

Research images, with clear evidence boundaries.

OCT and fundus have prepared outcomes. Chest X-ray replays a historical CheXpert calculation separate from NIH practice images.

Inspect what is demonstrated

Your evaluation

Your own task and references.

Measure errors, unresolved outputs, retained checking and clinical effort together against your current process.

See the evaluation method

The operating value

Measure the task removed.
Keep the remaining work in the calculation.

For OCT and fundus, compare extra verification or grading avoided with audits, retained checks, corrections and monitoring. Count setup and reassessment separately. Do not convert fewer task counts into saved clinical hours without measuring the time.

For chest X-ray, evaluate how single and unresolved outputs affect reading, corrections and usability. The coverage guarantee alone establishes no workload saving or accuracy guarantee for single answers.

Inspect the workload and usefulness measures

A concrete first step

Evaluate one imaging task against your current process.

Start retrospectively with one agreed task and population. Set the comparison and a useful outcome before changing the live workflow.

What you bring

One workflow. Its evidence.

  • The modality, finding or grade, intended population and the decision you want to change.
  • Original images or governed source access, versioned AI outputs and compatible scores.
  • Independent reference reviews, disagreements, quality flags and patient/site groupings.
  • Current checks, unresolved outputs, review volumes and clinical/product owners.

What the evaluation delivers

A basis for a deployment decision.

  • The supported task-specific risk statement and scope, where evidence permits it.
  • A comparison of your existing process, score-only policy and calibrated policy.
  • Errors, unresolved outputs, checks, audits, corrections and clinical time.
  • Integration and monitoring requirements, with a recommendation on a monitored pilot or further preparation.

No fixed saving, label count or deployment time is assumed. The result may support reduced checking, require further evidence or retain the current process.